Freezing Point Osmometer BK-FPO-V2

Additional information

Product Origin
Delivery Time

Supply Capacity

Introduction
The freezing point osmometer produced by our company with independent research and development is in accordance with Raoul freezing point theory, based on the solution freezing point declined value proportional to the solution molar concentration, using high sensitivity of temperature-sensing element, to measure the freezing point of different solutions, so as to derive the osmotic pressure molar concentration. This theory has been widely used for the test and research of osmotic pressure molar concentration in the fields such as pharmaceuticals, pharmaceutical analysis, biological and food therapy
Freezing Point Osmometer BK-FPO-V2.pdf

⚠This item is not returnable. View return policy

Description

Freezing Point Osmometer BK-FPO-V2

Feature:

1.It has the functions of electronic signature and user classification management, to satisfy CFR PART21 store data query according to time which can store 3 years of testing data.

2.It can carry on sing le-point or multi-point linear calibration, to ensure that the instrument has the detection accuracy of each range interval in stability.

3.Temperature probe adopts the screw linear guide motor design, So that the operation just on a touch screen can complete the whole test process.

4.It adopts double refrigeration system, with a short pre-cooling time, fast detection speed, to facilitate continuous detection.

5.It can simultaneously display the osmotic pressure molar concentration value, the freezing point value and the molar concentration ratio.

6.The cooling system adopts the athermal transfer fluid design, to exempt from frequent maintenance.

7.Built-in “Chinese pharmacopoeia” hundreds of injectable drug name can facilitate the preset information of test sample.

 

Technical Parameter:

Model BK-FPO-V2
Measurement Range 0~2000 mOsmol
Sample Amount 100μl
Testing Duration ≤3min
Pre-Cooling Time ≤3min
Measurement Error ≤1%
Repeatability ≤1%
Linearity ≤1%
Print Built-in printer
Audit Trail Optional
Environment Temperature 0~30℃ Recommended for 15~25℃
Relatively Humidity ≤60%
Power Supply 220V,50/60Hz (Standard); 110V, 60Hz (Optional)
External Size(W*D*H) 225*275*345mm
Packed Size(W*D*H) 420*545*580m
Net weight 12kg
Gross weight 25kg

 

 

Get news

SUBSCRIBE to our scientific newsletters every week - DON’T MISS OUT!

We don’t spam! Read our privacy policy for more info.

Additional information

Product Origin
Delivery Time

Supply Capacity

Request a quote. We'll respond as soon as possible.

Item: Freezing Point Osmometer BK-FPO-V2