Introduction
Equipped with the latest medical and technologicalinnovations, we have invented a state-of-the-artportable automatic biochemistry analyzer SMT-120which provides a better, quicker and accuratediagnosis for blood analysis.
Fully Automatic Dry Biochemistry Analyzer (POCT) SMT-120.pdf
Introduction:
The blood coagulation analyzer adopts the principle of optical colorimetry for detection. After the reagent is mixed with the plasma, fibrinogen is converted into fibrin and coagulated, which leads to the change of the optical density of the test specimen, and the instrument detects the coagulation end point.
Blood Coagulation Analyzer BK-CA02.pdf
Introduction:
ESR testing has important guiding significance for many clinical diseases, but the traditional standard Westergren method has complicated operation, low work efficiency and large cross-contamination. Automatic ESR analyzer uses advanced infrared light color difference interpretation technology to automatically scan the whole process of red blood cell sedimentation within 30 minutes for the sample of the vacuum blood collection tube, and refer to the Westergren method to measure the standard curve to obtain accurate results.
81-82 Auto ESR Analyzer BK-ESR20 & BK-ESR40.pdf
Introduction:
Auto ELISA Processor 4001 is a fully automatic detection equipment that integrates sample addition, incubation, shaking, washing, and reading. It is widely used in hospital laboratories, disease prevention and control centers, blood centers, and blood banks, animal and plant inspection and quarantine institutions, scientific research institutions, university laboratories and other places.
This product selects the ORF1ab and N gene regions of 2019-novel coronavirus, and designs two sets of specific primers and fluorescent probes that cover two sites of the gene at the same time. In order to control the entire extraction and detection process, human β-Globin gene was act as a non-competitive internal control during the extraction and detection process. The RT-PCR reaction solution is pre-mixed, which is convenient, efficient and easy to operate. It utilizes high-efficiency Taq DNA Polymerase and has strong stability. The kit could be used for auxiliary diagnosis and epidemiological surveillance of 2019-novel coronavirus infection.
53-54 Novel Coronavirus (2019-nCoV) Nucleic Acid Detection Kit (Fluorescence PCR).pdf
Features:
The instrument has a power-on self-test function to minimize the possibility of sample loss during the use of the instrument
Adopting a modular structure, the core components are all independently designed, with higher efficiency and lower failure rate, ensuring better stability during the operation of the instrument
Program visualization, precise control, simple operation, easy to use
According to user needs, the program can be freely edited
Suitable for a variety of nucleic acid methods based on biological nanomagnetic beads
Equipped with dual-channel HEPA filter system, easy to replace
Adopt large volume fan, strong ventilation
The operation area is reduced, and the experimental operation is fast
Nucleic Acid Extractor.pdf
Application:
Fibrinogen is the main protein in the coagulation process. In addition to the stress response under physiological conditions and the third trimester of pregnancy, FIB increase mainly occurs in acute infections, burns, atherosclerosis, acute myocardial infarction, autoimmune diseases, multiple Myeloma, diabetes, pregnancy-induced hypertension and acute nephritis, uremia, etc.; FIB reduction is mainly seen in DIC, primary hyperthyroidism, severe hepatitis, liver cirrhosis and thrombolytic therapy.
This kit is used to quantitatively determine the content of fibrinogen in human plasma in vitro for auxiliary diagnosis.
Thrombin Time (TT) Assay Kit & Fibrinogen (FIB) Assay Kit.pdf
Application:
TT reflects the level of fibrinogen in plasma and the amount of heparin-like substances in plasma. TT decreased when fibrinogen increased and fibrinogen decreased, otherwise TT increased. Can be used for the detection of heparin dosage.
This kit is used to measure thrombin time in human plasma samples in vitro.
Thrombin Time (TT) Assay Kit & Fibrinogen (FIB) Assay Kit.pdf
Application:
Prothrombin time is a screening test for exogenous coagulation factors, which is used to confirm the presence of congenital or acquired defects or inhibitors of fibrinogen, prothrombin, and coagulation factors V, VII, and X; At the same time, it is used to monitor the dosage of oral anticoagulants, which is the preferred indicator for monitoring oral anticoagulants. It can also be used as a detection index for the function of hepatic protein synthesis.
This kit is used for the determination of prothrombin time in human plasma in vitro for auxiliary diagnosis.
Activated Partial Thromboplastin Time (APTT) Assay Kit&Prothrombin Time (PT) Assay Kit.pdf
Application:
Activated partial thromboplastin time (APTT) is a screening test to check endogenous coagulation factors, and is used to confirm the deficiencies of congenital or acquired coagulation factors VI, IX, XI or the presence of their corresponding inhibitors; At the same time, APTT can also be used to confirm the deficiency of coagulation factor XI, prokallikrein and high molecular weight prokallikrein; due to the high sensitivity of APTT and the action pathway of heparin is mainly the endogenous coagulation pathway, APTT has become the preferred indicator for monitoring unfractionated heparin, with a ratio of 1.5-2.5 being the best.
This kit is used for the determination of activated partial thromboplastin time in human plasma in vitro for auxiliary diagnosis.
Activated Partial Thromboplastin Time (APTT) Assay Kit&Prothrombin Time (PT) Assay Kit.pdf