Description
Introduction:
The Automated Sample Processing System can be used with a biological safety cabinet. Could complete lid opening/closing, dispensing, proteinase K/internal control addition, it only takes 16 minutes to transfer 48 samples at one time, which helps laboratories quickly improve their large-scale nucleic acid detection capabilities
Application:
Sample processing for clinical diagnosis, epidemic surveillance, food safety, forensic identification, scientific research, etc., especially for samples of SARS-CoV-2 or other virulent infectious diseases.
Work Process:
Features:
Safety: Automated Sample Processing System is equipped with high-efficiency filter and built-in UV lamp, and it can be used with a biological safety cabinet, to effectively prevent aerosol pollution.
Efficient: Cooperative processing with dual robotic arms
Convenient: Visual interface operation, easy to operate
Compatibility: Compatible with a variety of pipette tips, deep well plates, sampling tubes.(including blood collection tubes) specifications
Smart: One-key operation, smart dispensation
Technical Parameter:
Model | BK-PR32 | BK-PR48 |
Throughput | 1-32 | 1-48 |
Processing Time | 32 samples/10min | 48 samples/16min |
Sample Type | Plasma, serum, whole blood,swab solution and other samples | |
Sample Rack | 1Pcs,3*12 with locking device (compatible with a variety of sampling tubes) |
1Pcs,6*8 with locking device(compatible with a variety of sampling tubes) |
RobotArm | 1 pcs (Dispensation arm ) | 2 pcs (Dispensation arm and Screw cap arm) |
Plate Position | 2 pcs(Compatible with l-shaped and square boards) |
3 pcs (Compatible with multi-specification deep-well plates) |
Tip Position | 3 pcs (Including tip waste box position) | |
Reagent Rack | 1 pcs (4*2ml centrifuge tube+4*2ml freezing tube+4*5ml freezing tube) | |
Protective Function | Can be used in a biological safety cabinet External droplet catch tray design With air-tight and anti-drip design |
|
Liquid Detection | Pneumatic liquid level detection principle, intelligent detection of blocked needle | |
Pipetting Volume | 5-100μl(1000/50μl Tip) | |
ipetting Accuracy | 10μl, CV≤1.5%,Accuracy≤6.0%,5oμl Tip 5oμl, CV≤1.0%,Accuracy≤2.0%,1000μlTip 100μl, CV≤0.5%,Accuracy≤2.0%,1000μl Tip |
|
Power Supply | 220V,50/60Hz;110V,60Hz | |
External Size (W”DH) | 540*637*1113mm | 827*794*1223mm |
Net Weight | 56kg | 100kg |
Package Size (W’DH) | 670*810*1314mm | Main instrument:925*925*817mm; Base cabinet:1030*995*1045 |
Gross Weight | 76kg | Main instrument:115kg; Base cabinet:105kg |