BK-AA4530F Atomic Absorption Spectrophotometer

Additional information

Product Origin
Delivery Time

Supply Capacity

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

⚠This item is not returnable. View return policy

Description

BK-AA4530F Atomic Absorption Spectrophotometer

Features:

* Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

* Integrated floated optical platform design improves the optical system shock resistance stable.

* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

* Position adjusting: the flame burner can be set on the best position automatically.

* Fully automated wavelength scanning and peak searching.

* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

* Deuterium lamp and self-absorption background calibration.

* Measuring method: flame absorption method and emission method.

* Result printing: parameter, data result and diagram.

* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

 

Technical Parameters:

Model BK-AA4530F
Wavelength Range 190~900nm
Spectral Bandwidth 0.1, 0.2, 0.4,1.0 and 2.0nm
Wavelength Accuracy ≤±0.15nm
Wavelength Repeatability ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Concentration 0.02μg/ml/1% (Cu)
Detection Limit 0.004μg/ml (Cu)
Preciseness ≤0.5%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 background Calibration When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Power Supply 220V, 50Hz
Packing Size(W*D*H) mm 860*705*755 (Main instrument); 545*445*1385 (Accessories)
Gross Weight(kg) 105 (Main instrument); 100 (Accessories)
Standard Accessories Software; Inkjet printer; Oil free Air compressor;

Acetylene reducing valve; Cu Hollow cathode lamp; Air filter

Optional Accessories Graphite Furnace 4510GF; Hollow cathode lamp(Ag, Au, Ca, Cd, Cr, Fe, Hg, K, Au, Mg, Mn, Na, Ni, Pb, Zn, Sb, etc), Graphite tubes, Recirculating cooling water system, Hydride generator, Autosampler

Flame System:

Acetylene Air Burner 100mm
Ignition Dynamic Baseline Drift ≤0.006A/30min
Characteristic Concentration ≤0.025μg/ml/1%(Cu)
Related Standard Deviation of the Accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphite Furnace(Optional):

Max. Temperature 3000°C
Max Heating Speed ≥2000°C/S
Characteristic Quantity Cd≤0.5*10T2g Cu≤0.5*1011g
Accuracy Cu≤3% Cd≤3%
Safety System Over current protection Low air pressure alarm/protection; Low cooling water flow alarm/protection
Power Supply 220V, 50Hz
Consumption 7000W
Packing Size(W*D*H) mm 740*640*700
Gross Weight(kg) 90

 

 